Cobalt

Test Code
345


Alias/See Also
LAB1020


CPT Codes
83018

Preferred Specimen
0.5 mL serum collected in a no additive (royal blue-top) tube


Minimum Volume
0.2 mL


Other Acceptable Specimens
Plasma collected in: EDTA (royal blue-top) tube


Instructions
Collect in a royal blue-top tube, centrifuge, and then pour into a trace metal-free plastic vial


Transport Container
Trace metal-free plastic vial


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 10 days
Refrigerated: 10 days
Frozen: 10 days


Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Tues-sat


Report Available
Same day


Reference Range
0.1-0.4 mcg/L


Performing Laboratory
Quest Diagnostics Nichols Institute-Chantilly VA
14225 Newbrook Drive
Chantilly, VA 20151-2228




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.