A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Amnisure Rupture of Membranes Test
MessageThis test uses immunochromatography to detect human PAMG-1 (placental alpha-1 microglobulin) protein which is present in amniotic fluid.
Test Code
AMNS
CPT Codes
84112
Preferred Specimen
Swab mixed with Collection Broth contained in Kit
Other Acceptable Specimens
none
Instructions
Must have collection broth vial for collection of specimen.
Transport Container
SPECIAL/1
Specimen Stability
30 min Room Temperature, 6 hrs refrigerated
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Performance of Amnisure has not been established in the presence of the following contaminants: meconium, anti-fungal creams or suppositories, K-Y Jelly, Baby Powder or baby oil.
Methodology
Immunochromatography
Setup Schedule
Daily on Receipt
Report Available
24/7
Reference Range
Negative Result indicates no Amniotic Fluid Detected
Positive Result indicates Amniotic Fluid Detected
Clinical Significance
Detection of amniotic fluid in vaginal discharge of pregnant patient with symptoms suggestive of ruptured membrane. This testing is used in conjunction with the algorithim used to determine premature delivery status.