Lead, Serum/Plasma

Test Code
12768


CPT Codes
83655<br>Limited Access Code

Preferred Specimen
1 mL serum collected in a trace metal-free, no additive (royal blue-top) tube


Minimum Volume
0.4 mL


Other Acceptable Specimens
Plasma collected in a trace metal-free EDTA (royal blue-top) tube


Instructions
Promptly centrifuge and separate serum or plasma into an acid-washed or trace metal-free plastic screw-capped vial using approved guidelines.


Transport Container
Acid-washed or trace metal-free, plastic screw-capped vial


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 30 days
Refrigerated: 30 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Polymer gel separation tube (SST or PST); Rejection criteria pertain to clinical sample submissions only


Methodology
Inductively Coupled Plasma-Mass Spectrometry

FDA Status
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.

Setup Schedule
Set up: Varies; Report available: 5 days


Reference Range
Normally less than 0.5 mcg/dL




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.