Calcitriol 1,25-Dihydroxyvitamin D

Test Code
16558


CPT Codes
82652

Includes
Vitamin D,1,25 (OH)2,Total
Vitamin D3, 1,25 (OH)2
Vitamin D2, 1,25 (OH)2


Preferred Specimen
0.6 mL serum


Minimum Volume
0.25 mL


Instructions
Collect blood in a red-top tube (no gel) (preferred) or serum separator tube. Allow blood to clot (30 minutes) at room temperature. Centrifuge and separate the serum from the cells and transfer serum to a clean transport tube.


Transport Container
Transport tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 28 days
Refrigerated: 28 days
Frozen: 28 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis • lipemia • Icteric specimens • Plasma


Methodology
Chromatography/Mass Spectrometry

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Mon-Sat; Report available: 3 days


Reference Range
Vitamin D, 1,25 (OH)2, Total  
1-9 Years 31-87 pg/mL
10-13 Years 30-83 pg/mL
14-17 Years 19-83 pg/mL
Adult 18-72 pg/mL
Vitamin D3, 1,25 (OH)2 Not available
Vitamin D2, 1,25 (OH)2 Not available
Reference ranges are established for total 1,25-dihydroxy vitamin D. Values for subcomponents D2 (derived from plant or fungal sources) and D3 (derived from human or animal sources) are provided for informational purposes only.


Clinical Significance
This test measures the bioactive form of vitamin D. It is used in the differential diagnosis of hypocalcemia and to monitor patients with renal osteodystrophy or chronic renal failure. This test is not suitable for diagnosis of vitamin D deficiency and monitoring supplementation in most patients. The 25-hydroxyvitamin D test is the recommended test for those purposes (N Engl J Med. 2007;357:266-281).




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.