Serotonin Release Assay (SRA), Unfractionated Heparin

Test Code
14627


CPT Codes
86022

Preferred Specimen
1 mL frozen serum


Minimum Volume
0.4 mL


Transport Container
Transport tube


Transport Temperature
Frozen


Specimen Stability
Room temperature: Unacceptable
Refrigerated: Unacceptable
Frozen: 6 months


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Received room temperature • Received refrigerated


Methodology
Radiobinding Assay (RBA)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Sun-Fri; Report available: 1-2 days


Reference Range
See Laboratory Report


Clinical Significance
Any patient with an unexplained fall in the platelet count of >40% during or after cessation of heparin therapy should be suspected of hit-heparin induced thrombocytopenia. This test is a functional assay of the PFU-antibody complex with heparin.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.