Drug Toxicology, Oral Fluid

Test Code
902545


CPT Codes
80307 (x4)<br>Limited Access Code

Includes
36862- Drug Tox Monitoring Base Panel with Confirmation, Oral
93976- Drug Toxicology Alcohol Metabolite, with Confirmation, Oral Fluid
93978- Drug Toxicology Barbiturates, w/Confirmation, Oral Fluid
93988- Drug Toxicology Phencyclidine, with Confirmation, Oral Fluid


Preferred Specimen
1 mL oral fluid inserted into 3 mL buffer tube collected in Quantisal™ device


Patient Preparation
Quantisal™: Avoid any food or drink consumption, or gum or tobacco use for 10 minutes prior to collecting. If donor's mouth is not empty immediately prior to collection, have subject rinse mouth with water (up to 4 oz) and wait a minimum of 10 minutes before collecting a specimen.

Minimum Volume
See specimen collection guidance for minimum


Instructions
Quantisal™: Using the standard Quantisal™ collection container, place the swab under the tongue. Donor should keep head down to allow gravity to help with saliva collection. Leave in place until blue dye indicates that the collection pad is saturated sufficiently. Follow collection instructions on package.


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 10 days
Refrigerated: 30 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Specimens submitted in a non-Quantisal™ collection device • Specimens received with any food debris or foreign objects present in the sample • Multiple swabs present in a single device • No swab present with the device • Quantisal™: collection wand inverted inside the collection tube


Methodology
All tests excluding THC: Mass Spectrometry (MS)
THC: Screen: Immunoassay (IA) • Confirmation: Mass Spectrometry (MS)

Setup Schedule
Set up and Report available: See individual tests


Reference Range
See Laboratory Report




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.