Circulating Immune Complex, C3 fragments

Test Code
10781


CPT Codes
86332

Preferred Specimen
1 mL serum


Minimum Volume
0.5 mL


Instructions
Specimen Preparation: Allow complete clotting of red blood cells (up to 1 hour), then separate serum from cells within 30 minutes and freeze immediately. Transport 1 mL serum. (Min: 0.5 mL) If ordered in conjunction with a C1q Binding Assay, transfer TWO (2) 1 mL aliquots of serum to individual Standard Transport Tubes.


Transport Container
Transport tube


Transport Temperature
Frozen


Specimen Stability
Room temperature: Unacceptable
Refrigerated: Unacceptable
Frozen: 20 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Non-frozen specimens • Specimens exposed to repeated freeze/thaw cycles • Grossly hemolyzed, lipemic, and icteric specimens


Methodology
Semi-Quantitative Enzyme-Linked Immunosorbent Assay

FDA Status
This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.

Setup Schedule
Monday, Thursday, Saturday Morning Report available: 9 Days


Reference Range
≤ 15 µg Eq/mL




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.