A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Base Panel with Alcohol and Methylphenidate
Test Code902388
CPT Codes
80307 (x5)<br>Restricted Client Code
Includes
93976 Drug Toxicology Alcohol Metab, w/Conf, Oral Fluid
93974 Drug Toxicology Methylphenidate, w/Conf,Oral Fluid
93974 Drug Toxicology Methylphenidate, w/Conf,Oral Fluid
Preferred Specimen
1 mL oral fluid inserted into 3 mL buffer tube collected in Quantisal™ device
Patient Preparation
Quantisal™: Avoid any food or drink consumption, or gum or tobacco use for 10 minutes prior to collecting. If donor's mouth is not empty immediately prior to collection, have subject rinse mouth with water (up to 4 oz) and wait a minimum of 10 minutes before collecting a specimen.
Minimum Volume
See specimen collection guidance for minimum
Instructions
Quantisal™: Using the standard Quantisal™ collection container, place the swab under the tongue. Donor should keep head down to allow gravity to help with saliva collection. Leave in place until blue dye indicates that the collection pad is saturated sufficiently. Follow collection instructions on package.
Transport Temperature
Refrigerated (cold packs)
Specimen Stability
Room temperature: 72 hours
Refrigerated: 30 days
Frozen: 30 days
Refrigerated: 30 days
Frozen: 30 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Specimens submitted in a non-Quantisal™ collection device • Specimens received with any food debris or foreign objects present in the sample • Multiple swabs present in a single device • No swab present with the device • Quantisal™: collection wand inverted inside the collection tube
Methodology
All tests excluding THC: Mass Spectrometry (MS)
THC: Screen: Immunoassay (IA) • Confirmation: Mass Spectrometry (MS)
FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Setup Schedule
Set up and Report available: See individual assays
Reference Range
See individual assays