SARS CoV 2, QuantiFERON®, Blood

Test Code
10389


CPT Codes
86480<br>Restricted Client Code

Preferred Specimen
6 mL whole blood collected in a sodium heparin or lithium heparin (green-top) tube


Minimum Volume
6 mL


Instructions
Collect a minimum of 6 mL of blood by venipuncture into a lithium heparin (green-top) tube. Gently mix by inverting the tube several times to dissolve the heparin. Blood drawn into a heparin tube may be held at room temperature (17-25°C) for no longer than 3 hours after blood collection.

Refrigerate at 2-8°C


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: Unacceptable
Refrigerated: 48 hours
Frozen: Unacceptable


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Quantiferon® - SARS-CoV-2 Blood Collection tubes • Incubated specimens • Gel barrier lithium heparin (green-top) tubes


Methodology
Immunoassay

FDA Status
This test was performed using a kit that has not been cleared or approved by the FDA. The analytical performance characteristics of this test have been determined by Quest Diagnostics. This test should not be used for diagnosis without confirmation by other medically established means.

Setup Schedule
Set up: Daily; Report available: 2 days


Reference Range
See Laboratory Report


Clinical Significance
The SARS COV 2 - QUANTIFERON(R) ELISA (RUO) test is an interferon-gamma release assay (IGRA) to detect a cell-mediated response to SARS-CoV-2. This test uses a combination of peptide antigens specific to SARS-CoV-2 to stimulate lymphocytes in heparinized whole blood involved in cell-mediated immunity. Detection of interferon gamma by ELISA is used to identify in vitro responses to those peptide antigens that maybe associated with SARS-CoV-2 infection. The SARS COV 2 - QUANTIFERON(R) ELISA test is for Research Use Only and not for diagnostic use.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.