Benzodiazepines, Serum

Test Code
70071


CPT Codes
80346

Includes
Alprazolam, Alpha-Hydroxyalprazolam, Alpha-Hydroxytriazolam, Chlordiazepoxide, Clonazepam, Desalkylflurazepam, Diazepam, Lorazepam, Midazolam, Norchlordiazepoxide, Nordiazepam, Oxazepam, Temazepam, Triazolam


Preferred Specimen
2 mL serum collected in a red-top tube (no gel)


Minimum Volume
1 mL


Transport Temperature
Frozen


Specimen Stability
Room temperature: 24 hours
Refrigerated: 72 hours
Frozen: 14 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gel barrier/Serum Separator Tube


Methodology
Chromatography/Mass Spectrometry

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Tuesday, Thursday, Saturday Morning
Report available: 4 Days


Reference Range
Temazepam 50-1000 ng/mL
Oxazepam  
  Therapeutic 200-500 ng/mL
  Potentially toxic >2000 ng/mL
Chlordiazepoxide 100-3000 ng/mL
Norchlordiazepoxide 100-3000 ng/mL
Nordiazepam 100-1500 ng/mL
Alprazolam 10-50 ng/mL
Alpha-Hydroxyalprazolam 5-25 ng/mL
Alpha-Hydroxytriazolam 5-20 ng/mL
Clonazepam 30-60 mcg/L
Desalkylflurazepam 30-150 ng/mL
Diazepam 100-1500 ng/mL
Lorazepam 50-240 ng/mL
Midazolam 50-600 ng/mL
Triazolam 5-20 ng/mL


Clinical Significance
Benzodiazepines are widely used as anxiolytics, sedative- hypnotics, muscle relaxants, and anticonvulsants. Benzodiazepines include drugs such as diazepam Valium®, chlordiazepoxide Librium®, oxazepam Serax®, lorazepam Ativan®, alprazolam Xanax®, clonazepam Clonopin® and triazolam Halcion®. Many common benzodiazepines are detected in urine by their metabolites oxazepam and nordiazepam. Psychological and physiological addictions, misuse and abuse of benzodiazepines have been described.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.