Barium, Serum/Plasma

Test Code
5375


CPT Codes
83018

Preferred Specimen
1 mL serum collected in no additive, trace metal-free (royal blue-top) tube


Minimum Volume
0.4 mL


Other Acceptable Specimens
Plasma collected in an EDTA, trace metal-free (royal blue-top) tube


Instructions
Collect sample in a plastic container. Promptly centrifuge and separate serum or plasma in an acid-washed plastic screw-capped vial using approved guidelines.


Transport Container
Acid-washed plastic screw-capped vial


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 30 days
Refrigerated: 30 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Glass container • Serum separator tube • Polymer gel separation tube


Methodology

Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) 



FDA Status
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.

Setup Schedule
Set up: As needed; Report available: 5 days


Report Available
5 Days


Reference Range
See Laboratory Report




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.