Paraldehyde and Metabolite, Serum/Plasma
Test Code691
CPT Codes
80299
Includes
Paraldehyde and Acetaldehyde
Preferred Specimen
2 mL serum collected in a red-top tube (no gel)
Minimum Volume
0.7 mL
Other Acceptable Specimens
Plasma collected in a sodium fluoride/oxalate (gray-top) tube
Instructions
Promptly centrifuge and separate serum or plasma into a plastic screw-cap vial.
The use of serum separator tubes is not acceptable. Submission of a serum separator tube will result in cancellation.
Note: Immediately process sample after collection and store at frozen conditions both post-collection and during transport to lab.
The use of serum separator tubes is not acceptable. Submission of a serum separator tube will result in cancellation.
Note: Immediately process sample after collection and store at frozen conditions both post-collection and during transport to lab.
Transport Container
Plastic screw-cap vial
Transport Temperature
Frozen
Specimen Stability
Room temperature: Unacceptable
Refrigerated: Unacceptable
Frozen: Undetermined
Refrigerated: Unacceptable
Frozen: Undetermined
Methodology
Headspace Gas Chromatography (GC)
FDA Status
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.
Setup Schedule
Set up: As needed; Report available: 5 days
Report Available
5 Days
Reference Range
Normal: Up to 0.02 mg/dL in blood
Clinical Significance
Scope of Analysis: Paraldehyde, Acetaldehyde