A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Sinemet®, Serum/Plasma
Test Code3388
CPT Codes
80299 (x2)
Includes
Levodopa and Carbidopa
Preferred Specimen
1 mL serum collected in a red-top tube (no gel)
Minimum Volume
0.3 mL
Other Acceptable Specimens
Plasma collected in: EDTA (lavener-top) tube or EDTA (pink-top) tube
Instructions
Promptly centrifuge and separate serum or plasma into a plastic screw-cap vial.
Freeze immediately. Transport on dry ice.
Freeze immediately. Transport on dry ice.
Transport Temperature
Frozen
Specimen Stability
Room temperature: Not stable
Refrigerated: Not stable
Frozen -20° C: 6 days
Frozen -70° C: 30 days
Refrigerated: Not stable
Frozen -20° C: 6 days
Frozen -70° C: 30 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Received room temperature • Received refrigerated • Serum separator tube (SST) • Polymer gel separation tube
Methodology
High Performance Liquid Chromatography (HPLC)
FDA Status
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.
Setup Schedule
Set up: As needed; Report available: 8 days
Report Available
8 Days
Reference Range
Levodopa 0.020 mcg/mL
Carbidopa 0.020 mcg/mL
Carbidopa 0.020 mcg/mL
Clinical Significance
Therapeutic drug monitoring.