Opiates - Total (Conjugated/Unconjugated), Serum/Plasma

Test Code
11053


CPT Codes
80361, 80365, (G0480)

Includes
Dihydrocodeine/Hydrocodol- Total; Codeine - Total; Morphine - Total; Hydrocodone - Total; Hydromorphone - Total; Oxycodone - Total; Oxymorphone - Total


Preferred Specimen
1 mL serum collected in a red-top tube (no gel)


Minimum Volume
0.2 mL


Other Acceptable Specimens
Plasma collected in an EDTA (lavender-top), or EDTA (pink-top) tube


Instructions
Promptly centrifuge and separate serum or plasma into a plastic screw-capped vial using approved guidelines.


Transport Container
Transport tube


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: 48 hours
Refrigerated: 30 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Polymer gel separation tube (SST or PST) • Received room temperature


Methodology
Liquid Chromatography/Tandem Mass Spectrometry

FDA Status
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.

Setup Schedule
Set up: As needed; Report available: 5 days


Report Available
5 Days


Reference Range
See Laboratory Report


Clinical Significance
Identification and Quantitation by LC-MS/MS.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.