Venous Thrombosis Hypercoag Panel w/Reflex, Consultation (Warfarin Patient)

Test Code
19655


CPT Codes
81240, 85307, 85300, 85240, 83090, 86147 (x2), 86146 (x2), 85598, 85613 <br>Dependent on the complexity of the consultation, 80503 or 80504 or 80505 may be assigned. 80506 may also be billed if high complexity with more than 60 minutes of time spent for the consultation.

Includes
Activated Protein C Resistance with Reflex to Factor V (Leiden) Mutation
Prothrombin (Factor II) 20210G→A Mutation Analysis 
Antithrombin III Activity
Homocysteine
Cardiolipin Antibodies (IgG, IgM)
Factor VIII Activity, Clotting
Beta-2-Glycoprotein I Antibodies (IgG, IgM)
Hexagonal Phase Confirmation
dRVVT Screen with Reflex to dRVVT Confirm and dRVVT 1:1 Mix
Coagulation Consultation 

If Activated Protein C-Resistance is <2.1 ratio, then Factor V (Leiden) Mutation Analysis will be performed at an additional charge (CPT code(s): 81241).

If dRVVT Screen is prolonged (>45 seconds), then dRVVT Confirm will be performed at an additional charge (CPT code(s): 85597).
If dRVVT Confirm is positive, then dRVVT 1:1 Mixing Study will be performed at an additional charge (CPT code(s): 85613).


Preferred Specimen
5 mL whole blood collected in EDTA (lavender-top) tube, and
1 mL platelet-poor plasma collected in six separate 3.2% sodium citrate (light blue-top) tubes, and
1 mL serum


Minimum Volume
3 mL whole blood • 0.5 mL (x6) frozen platelet-poor plasma • 0.6 mL serum


Instructions
Whole blood sample is for the Factor V Mutation Analysis and Prothrombin (Factor II) Mutation Analysis. Serum sample is for the Homocysteine. Platelet-poor plasma is for the remaining tests.

Red top tubes: Place the specimen in a refrigerator or ice bath for 30 minutes after collection. Centrifuge the specimen as soon as possible after complete clot formation has taken place. Transfer the serum to a plastic screw-capped vial.

Barrier gel separator tubes: Place the specimen in a refrigerator for 30 minutes after collection. Centrifuge the specimen as soon as possible after complete clot formation has taken place. Do not place barrier tubes in an ice bath as freezing may prevent the barrier gel from adequately separating serum from cells. Platelet-poor plasma is for remaining tests.

Platelet-poor plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 x g within 60 minutes of collection using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into six new plastic vials. Plasma must be free of platelets (<10,000/mcL).

Note: Storage of whole blood at refrigerated temperatures prior to processing may lead to cryoprecipitate formation and falsely low Factor VIII and von Willebrand Factor studies. Aliquot plasma into 3-6 transport tubes. Freeze immediately and ship on dry ice.


Transport Temperature
Whole blood and serum: Room temperature
Plasma: Frozen


Specimen Stability
Whole blood
Room temperature: 8 days
Refrigerated: 8 days
Frozen: 30 days

Plasma
Room temperature: Unacceptable
Refrigerated: Unacceptable
Frozen: 14 days

Serum
Room temperature: 4 days
Refrigerated: 14 days
Frozen: 6 months


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
See individual assays


Methodology
See individual tests

FDA Status
*This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up and Report available: See individual assays


Reference Range
See Laboratory Report


Clinical Significance
This panel evaluates for the most common hereditary and acquired venous thrombophilia risk factors except for Protein C and S.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.