A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Glucose, Gestational Screen (50g)-135 Cutoff
Test Code8477
CPT Codes
82950
Preferred Specimen
1 mL timed plasma collected in a fluoride oxalate (gray-top) tube
Patient Preparation
Fasting is not required. The patient is given a 50 g dose of glucose and a single blood specimen is obtained 1 hour later.
Minimum Volume
0.5 mL
Other Acceptable Specimens
Plasma collected in: sodium or lithium (green-top) tube • Timed, full tube of whole blood collected in: fluoride oxalate (gray-top) tube • Timed serum collected in serum separator tube (SST®)
Instructions
Serum and plasma submissions must be separated from cells.
Please note: The test should be performed between weeks 24 and 28 of gestation.
Please note: The test should be performed between weeks 24 and 28 of gestation.
Transport Temperature
Room temperature
Specimen Stability
Plasma
Room temperature: 7 days
Refrigerated: 7 days
Frozen: 28 days
Serum
Room temperature: 4 days
Refrigerated: 7 days
Frozen: 28 days
Whole blood
Room temperature: 24 hours
Refrigerated: 72 hours
Frozen: Unacceptable
Room temperature: 7 days
Refrigerated: 7 days
Frozen: 28 days
Serum
Room temperature: 4 days
Refrigerated: 7 days
Frozen: 28 days
Whole blood
Room temperature: 24 hours
Refrigerated: 72 hours
Frozen: Unacceptable
Methodology
Spectrophotometry (SP)
Setup Schedule
Set up: Daily; Report available: Next day
Limitations
Glucose levels may be depressed if sample is left on clot for an excessive length of time.
Reference Range
<135 mg/dL
Clinical Significance
A value of 135 mg/dL or greater indicates the need for a full diagnostic, gestational glucose tolerance performed in the fasting state to determine if the patient has gestational diabetes.