Respiratory Virus PCR Panel IV

Test Code
91233


CPT Codes
87632

Includes
Adenovirus DNA, Qualitative, Real-Time PCR
Human Metapneumovirus RNA, Qualitative, Real-Time PCR
Influenza A and B RNA, Qualitative Real-Time PCR
Parainfluenza Virus (Types 1, 2, 3 and 4) RNA, Qualitative, Real-Time PCR
Rhinovirus RNA, Real-Time PCR
Respiratory Syncytial Virus (RSV) RNA, Qualitative Real-Time PCR


Preferred Specimen
1 nasopharyngeal or oropharyngeal swab submitted in 3 mL, M4 media, VCM, UTM or equivalent, or
2 mL bronchial lavage collected in a plastic, sterile, leak-proof container


Minimum Volume
0.6 mL


Instructions
Quest Diagnostic Patient Service Centers and Quest in-office phlebotomists do not collect respiratory specimens, including those from patients suspected to have COVID-19.


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Swabs
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 30 days

Bronchial lavage
Room temperature: Unacceptable
Refrigerated: 7 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Sputum


Methodology
Real-Time Polymerase Chain Reaction • Real-Time Reverse Transcriptase Polymerase Chain Reaction (RT-PCR)

Setup Schedule
Set up: Daily; Report available: 2 days


Reference Range
See individual tests


Clinical Significance
This test is used to determine the presence of respiratory virus RNA/DNA in a patient's specimen. PCR provides more rapid results than other methods, including culture. The use of a panel for virus detection provides a useful differential diagnosis.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.