| A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Interleukin 17, Serum
Test Code36625
CPT Codes
83520
Preferred Specimen
1 mL frozen serum
Minimum Volume
0.4 mL • 0.2 mL pediatric
Instructions
CRITICAL FROZEN: Separate serum from cells within 2 hours of collection. Transfer 1 mL serum to a Standard Transport Tube. Freeze serum within 30 minutes.
Transport Temperature
Frozen
Specimen Stability
Room temperature: Unacceptable
Refrigerated: Unacceptable
Frozen: 1 year
Refrigerated: Unacceptable
Frozen: 1 year
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Contaminated specimens • Heat-inactivated specimens
Methodology
Quantitative Multiplex Bead Assay
FDA Status
This test was developed and its performance characteristics determined by ARUP Laboratories. The U.S. Food and Drug Administration has not approved or cleared this test; however, FDA clearance or approval is not currently required for clinical use. The results are not intended to be used as the sole means for clinical; diagnosis or patient management decisions.
Setup Schedule
Set up: Daily; Report available: 1-4 days
Reference Range
≤2.1 pg/mL
Clinical Significance
Primarily used for research and to support attempts to understand the pathogenesis of immune, infectious, allergic, or inflammatory disorders.