Clostridium difficile Culture with Reflex to Toxin B, Real-Time PCR,Isolate

Test Code
QCDCX


Quest Code
92014


CPT Codes
87081

Includes
If Clostridium difficile Culture is Isolated, then Clostridium difficile Toxin B, Qualitative Real-time PCR, Isolate will be performed at an additional charge (CPT code(s): 87493)


Preferred Specimen
5 g or 5 mL unpreserved stool collected in a sterile screw-cap container


Minimum Volume
2 g or 2 mL


Instructions
Toxin is heat labile. Freeze as soon as possible. Submit frozen stool in sterile screw-cap container.


Transport Container
Screw-cap container


Transport Temperature
Frozen


Specimen Stability

Room temperature: Unacceptable
Refrigerated: 48 hours
Frozen -20° C: Not established
Frozen -70° C: 7 days



Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Received room temperature • Received in Cary-Blair transport • Specimen other than liquid or semi-formed stool • Stool in preservative or mixed with urine • Specimen in wrong transport container


Methodology
Conventional Culture

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Daily


Report Available
5-8 days


Reference Range
Clostridium difficile Culture Not isolated


Clinical Significance
C. difficile causes 50-75% of antibiotic associated colitis and greater than 90% of antibiotic associated pseudomembranous colitis. Pathogenic C. difficile produce two potent toxins, toxin A and toxin B, that cause diarrhea and colitis.


Performing Laboratory
Quest Diagnostics Nichols Institute-Chantilly VA
14225 Newbrook Drive
Chantilly, VA 20151-2228




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.