Lactate Dehydrogenase (LD)

Message
Performed in the Chemistry Laboratory x5820
10.2018


Test Code
LD


Alias/See Also
LDH


CPT Codes
83615

Preferred Specimen
Plasma from a green top (PST) tube


Minimum Volume
1 mL


Instructions
Centrifuge within 2 hours of collection


Transport Container
Green Top (PST) tube


Transport Temperature
Room Temperature


Specimen Stability
2 - 8 oC: 4 days


Methodology
Lactate to Pyruvate

Setup Schedule
This assay is performed 24 hours per day, 7  days per week


Reference Range
120 - 220  IU/L


Clinical Significance
This test is used in the diagnosis and treatment of liver diseases.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.