HIV 1/2 Antibody

Message
This assay is performed using the  4th generation HIV test (Abbott Architect), measuring both antibody and p24 antigen.
Reactive samples are sent to a reference laboratory for Western Blot testing.
Performed in the Chemistry Laboratory, x5820
10.2018


Test Code
HIV


CPT Codes
86703

Preferred Specimen
Plasma from a green top (PST) tube


Minimum Volume
1mL


Transport Container
Green Top (PST) tube


Transport Temperature
Room temperature


Specimen Stability
2 - 8 oC: 7 days


Methodology
Chemiluminescent Microparticle Immunoassay (Abbott Architect)

Setup Schedule
This assay is performed 24 hours per day, 7 days per week. 
May be requested STAT for a needlestick patient.


Reference Range
Non Reactive


Clinical Significance
This test is used in the diagnosis of HIV infection




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.