Crossmatch (Flow Cytometry)

Message
Performed by the HLA Molecular Pathology Laboratory.  x5791 or x5793
This test is performed as the preliminary and final crossmatch between the recipient and chosen donor.
 


Test Code
X-AlloFXM-Pre / X-AlloFXM-Final


CPT Codes
86825

Includes
Crossmatch for T and B cells


Preferred Specimen
Whole blood and serum


Minimum Volume
Collection vials (see below) must be full.


Instructions
Phlebotomist must initial tube and requisition for positive identification of both the recipient and donor(s) 


Transport Container
6, 10mL Yellow tops (ACD) and 2, 10mL Red tops


Transport Temperature
Room Temperature


Specimen Stability
Room Temperature:  48 hours


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis,  QNS, Clotted


Methodology
Flow cytometric analysis of fluorescent antigen/antibody complexes

Setup Schedule
M-F 8-4pm, as scheduled by Renal Transplant Clinic


Report Available
In Presidio (Teleresult)


Limitations
Increased sensitivity may result in the detection of weak antibodies.


Reference Range
Negative


Clinical Significance
To assess compatibility of donor and recipient for solid organ transplantation.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.