Digoxin

Message
Serum half-life is 30 - 45 hours
Performed in the Chemistry laboratory x5820.
10.2018


Test Code
DIG


CPT Codes
80162

Preferred Specimen
Plasma from a green top (PST) tube


Minimum Volume
1 mL


Instructions
Therapeutic monitoring: TROUGH: collect just prior to next dose. May also be collected within 6 - 8 hours after IV dose or oral dose.

Draw specimen  at steady state reached at approximately 5 - 7 days. 


Transport Container
Green Top (PST) tube


Transport Temperature
Room temperature


Specimen Stability
No Add-On


Methodology
Chemiluminescent microparticle immunoassay (CMIA on the Architect i 2000)

Setup Schedule
This assay is performed 24 hours per day, 7 days per week


Limitations
Digibind drug therapy affects immunoassay results


Reference Range
Therapeutic range: 0.8 - 2.0 ng/mL
Critical alert value:  3 ng/mL


Clinical Significance
This test is used to monitor compliance, assess clinical effectiveness, or determine toxicity.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.