Atypical pneumonia panel

Message
Performed in the MicrobiologyLaboratory x5785
Nasopharyngeal specimens also suitable for Influenza by PCR and/or RSV by the RVP test  
**For lower respiratory specimens, virology culture  please order CXVIR**


Test Code
APNEU


Alias/See Also
Mycoplasma pneumoniae, Chlamydophiala pneumoniae, Bordetella pertussis


CPT Codes
87581, 87486, 87796

Includes
Mycopasma pneumoniae, Chlamydophila pneumoniae, Bordetella pertussis  


Preferred Specimen
Nasopharyngeal swab in viral transport media


Minimum Volume
2 mL


Other Acceptable Specimens
Please obtain special flocked swab collection kit directly from Microbiology lab.


Instructions
Nasopharyngeal swab:
Detailed instructions come with each collection kit, obtained from Microbiology lab, 6-5785.
Insert (flocked end with thin flexible shaft) through nose into the posterior nasopharynx and, rotate the swab.
Keep the swab near the septum and floor of the nose.
Place the inoculated swab into the UTM medium and break off the shaft where scored.
Fit the top of the shaft into the lid of the tube and screw top onto tube securely. 


Transport Container
Washing or suction: Sterile catheter trap container.
Swab: VTM provided with collection kit.


Transport Temperature
Room temperature if transported within 15 minutes.
On ice if transport will be delayed >15 min.


Methodology
PCR

Setup Schedule
Test performed Sunday through Saturday


Report Available
yes


Limitations
For patients with symptoms of Atypical pneumonia. If patient is immunocompromised, critically ill due to respiratory infection or a pediatric patient at high risk for severe complications due to cardiopulmonary disease, consider RVP panel. Call 65785 Microbiology


Reference Range
Not Detected


Performing Laboratory
Microbiology x65785 Tufts Medical Center



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.