Urine Eosinophils

Message
Performed in the Hematology Laboratory x5475, 76


Test Code
UEO


CPT Codes
87205

Preferred Specimen
Urine


Minimum Volume
1 mL


Transport Container
Plastic, Leakproof Container with screw cap. 


Transport Temperature
Store refrigerated until transported to laboratory


Specimen Stability
Stable refrigerated for 6 hours
Stable for 1 hour unrefrigerated


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Sample too old for testing (see above)


Methodology
Manual stain and differential

Setup Schedule
24/7


Limitations
Samples with extremely high or low pH can result
in lysis of eosinophils resulting in falsely low
eosinophil counts.


Reference Range
< 1%


Clinical Significance
  >2 eos,  Consider allergic interstitial nephritis; Consider other causes of eosinophiluria.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.