Ammonia

Message

SRHC Clients:

Note special collection and transport requirements due to specimen stability.

Outreach/Outpatients:
 

  • 1 lime green top(preferred)  - place on ice and transport immediately following collection as sample MUST be received in laboratory within 20 minutes of collection for testing
  • If immediate transport is delayed or not possible:  centrifuge sample, remove and refrigerate plasma immediately (within 20 minutes of collection).  Transport to SRHC refrigerated in a transport tube marked "plasma". Transport with a frozen gel pack.  Sample stable for 2 hours refrigerated.

Inpatients:
 

  • 1 lime green top(preferred) - place on ice and transport to lab immediately as sample MUST be received in laboratory within 20 minutes of collection for testing


Test Code
NH3


Alias/See Also
NH3


CPT Codes
82140

Preferred Specimen

1 lime green top tube  - See Instructions

 




Instructions
Immediately following collection, place tube on ice and transport immediately to laboratory as sample MUST be received in laboratory within 20 minutes of collection for testing.

If immediate transport is delayed or not possible:  Centrifuge sample, remove and refrigerate plasma immediately (within 20 minutes of collection).


Transport Container
1 lime green tube - transport on ice (within 20 minutes of collection)

Plastic transport vial marked "plasma" if  sample was centrifuged and refrigated for transport. Transport on frozen gel pack.


Transport Temperature

On ice for immediate transport (within 20 minutes of collection)  to laboratory

Refrigerate centrifuged and aliquoted plasma if transport is delayed longer than 20 minutes. Stable 2 hours refrigerated.
 




Specimen Stability

On ice: 20 minutes

Refrigerated: 2 hours


 




Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis
Lipemia
Icterus


Methodology
Enzymatic

Report Available
4-8 hrs




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.