A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Cortisol, Free, Response to ACTH Stimulation
Test Code16434
CPT Codes
82530 (x3)
Includes
Cortisol, Free: Baseline, 30 minutes, 60 minutes
Preferred Specimen
2 mL serum for each timed specimen collected in a red-top tube (no gel)
Minimum Volume
0.7 mL for each timed specimen
Other Acceptable Specimens
Plasma collected in: EDTA (lavender-top) tube or PPT potassium (white-top) tube
Instructions
Draw morning baseline specimen. Administer 250 mcg Cortrosyn. Draw additional specimens at 30 and 60 minutes.
For each timed specimen submitted, each tube must be clearly marked with time drawn. Submit all tubes with one test request form.
Note: Cortrosyn (cosyntropin) not supplied by the laboratory.
This test cannot be collected at a Patient Service Center.
For each timed specimen submitted, each tube must be clearly marked with time drawn. Submit all tubes with one test request form.
Note: Cortrosyn (cosyntropin) not supplied by the laboratory.
This test cannot be collected at a Patient Service Center.
Transport Container
Transport tube(s)
Transport Temperature
Refrigerated (cold packs)
Specimen Stability
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 2 years
Refrigerated: 7 days
Frozen: 2 years
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis • Received room temperature • Serum separator tubes (SST)
Methodology
Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS) • Equilibrium Dialysis
FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Reference Range
Cortisol, Free, Baseline | 8:00-10:00 A.M. | 0.07-0.93 | µg/dL |
Adult | 4:00-6:00 P.M. | 0.04-0.45 | µg/dL |
10:00-11:00 P.M. | 0.04-0.35 | µg/dL | |
Cortisol, Free, 30 min | Not established | ||
Cortisol, Free, 60 min | Not established |
Clinical Significance
Free Cortisol is useful in the detection of patients with Cushing’s syndrome for whom Free Cortisol concentrations are elevated.
Performing Laboratory
Quest Diagnostics Nichols Institute-San Juan Capistrano, CA |
33608 Ortega Highway |
San Juan Capistrano, CA 92675-2042 |
Last Updated: November 6, 2024