A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Carbon Dioxide
Test Code310
CPT Codes
82374
Preferred Specimen
1 full unopened spun gel barrier tube
Minimum Volume
0.5 mL
Other Acceptable Specimens
Plasma collected in: Sodium heparin (green-top) tube or lithium heparin (green-top) tube
Instructions
Do not open tube
Transport Container
1 full unopened spun gel barrier tube
Transport Temperature
Room temperature
Specimen Stability
Room temperature: 72 hours
Refrigerated: 72 hours
Frozen: 31 days
Refrigerated: 72 hours
Frozen: 31 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Anticoagulants other than heparin • Red-top tube (no gel)
Methodology
Spectrophotometry (SP)
Setup Schedule
Daily
Report Available
1 day
Limitations
Proper specimen collection and processing are critical for reliable testing.
Reference Range
20-32 mmol/L
Clinical Significance
Measurements are used in the diagnosis and treatment of numerous potentially serious disorders associated with changes in body acid-base balance.
Performing Laboratory
Quest Diagnostics-Seattle |
1737 Airport Way S Suite 200 |
Seattle, WA 98134-1636 |