Cystine Quantitative, Urine

Test Code
13810


CPT Codes
82131

Includes
Creatinine


Preferred Specimen
4 mL frozen 24-hour or other timed urine collection, collected in a 24-hour collection container


Minimum Volume
3 mL


Instructions
Avoid dilute urine when possible. Refrigerate 24-hour/timed specimens during collection.

Mix urine well. Transfer a 4 mL aliquot of urine to a standard transport tube and freeze immediately. Record total volume and collection time interval on transport tube and test request form.

Critical frozen. Separate specimens must be submitted when multiple tests are ordered.

Clinical information is needed for appropriate interpretation. Additional required information includes age, gender, diet (eg, TPN therapy), drug therapy, and family history. Biochemical Genetics Patient History Form is available on the ARUP Web site or by contacting ARUP client services.


Transport Container
24-hour collection container


Transport Temperature
Frozen


Specimen Stability
Room temperature: Unacceptable
Refrigerated: Unacceptable
Frozen: 30 days


Methodology
Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

FDA Status
This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.

Setup Schedule
Daily


Report Available
4-9 days


Reference Range
See Laboratory Report


Clinical Significance
This test is indicated only to monitor patients with cystinuria on therapy. Use for monitoring treatment of patients previously diagnosed with cystinuria. To diagnose or rule out cystinuria, refer to Cystinuria Panel or Amino Acids Quantitative by LC-MS/MS, Urine.


Performing Laboratory
A.R.U.P. , Inc.
500 Chipeta Way
Salt Lake City, UT 84108-1221



Last Updated: November 6, 2024


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.