Monkeypox (Orthopoxvirus), PCR (LABCORP)

Test Code
1231102032


Alias/See Also
LAB2169: Monkeypox (Orthopoxvirus), PCR | LABCORP EAP: 140230


CPT Codes
87593x1

Preferred Specimen
LABCORP LAB: VIRAL TRANSPORT MEDIA (Refrigerated) Min Vol: 1


Instructions
Preferred specimen:  One Dry swab (polyester) placed in Viral Transport Media


 


Special instructions: Vigorously swab or brush the base of the lesion with a sterile dry polyester, rayon or Dacron swab. Insert the swab into the tube containing VTM. Carefully break the swab at the score line and tightly close the sample. If multiple lesions with differing appearances are present, consider submitting an additional VTM collection, as described above, for each lesion.

Specimen: Dry swab (polyester)
Volume: One swab in VTM
Minimum Volume: One swab in VTM
Specimen Container: Viral Transport Media (VTM)
Specimen Collection: Vigorously swab or brush the base of the lesion with a sterile dry polyester, rayon or Dacron swab. Insert the swab into the tube containing VTM. Carefully break the swab at the score line and tightly close the sample. If multiple lesions with differing appearances are present, consider submitting an additional VTM collection, as described above, for each lesion.
Transport Temperature: Refrigerated
Stability:
             Room Temp: Unacceptable
             Refrigerate: 7 days
             Frozen: 30 days
Turn-around-time (From date of pickup of specimen by Labcorp): 3-4 days
Cause for Rejection: Improperly submitted specimens including swabs submitted with 0.9% saline or liquid Amies (E-Swabs). Swab specimens submitted in aerobic or anaerobic transport devices.


Transport Temperature
Specimen Storage: Room Temperature Stability: Room Temp: Unacceptable Refrigerated: 7 days Frozen: 30 days


Report Available
LABCORP LAB STAT: 4 Days



Last Updated: June 22, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.