Histone Ab (Labcorp) (LABCORP)

Test Code
1230120165


Alias/See Also
LAB7293: Histone Antibody | LABCORP EAP: 012518


CPT Codes
86235x1

Preferred Specimen
LABCORP LAB: Serum Separator Tube (Room Temperature) Min Vol: .5


Other Acceptable Specimens
LABCORP LAB: RED TOP - PLAIN: (Room Temperature) Min Vol: .5


Instructions
10 mL Random Urine Use random urine transport tube containing 6N HCl or urine Monovette® with pH stabilizer (LabCorp N° 56015). Monovette® instructions accompany units. Preservative must be added to the container prior to the start of the collection. If collecting without Monovette®, use plastic urine container and adjust urine pH to <5 with 6N HCI. Caution: Strong acid. May cause skin burns.


Transport Temperature
Storage instructions: Refrigerate


Report Available
LABCORP LAB
STAT: 5760 min
Routine: 5760 min
Extended TAT: No TAT min
Timed: 5760 min
Life or Death: 5760 min



Last Updated: March 6, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.