Creatine Kinase, MB

Test Code
2140


Alias/See Also
CARDIAC ENZYME; CK, MB; ISO ENZYME; CK ISOENYME


Preferred Specimen
One 3 mL green (sodium or lithium heparin), plasma separator tube, or 4 mL serum separator tube.


Minimum Volume
2 mL plasma or serum, frozen. (Min: 0.5 mL)  Submit specimen in an ARUP Standard Transport Tube.


Transport Temperature
2 mL plasma or serum, frozen. (Min: 0.5 mL)  Submit specimen in an ARUP Standard Transport Tube.


Specimen Stability
After separation from cells: Ambient: 8 hours; Refrigerated: 2 days; Frozen: 6 months


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Specimens exposed to repeated freeze/thaw cycles.


Methodology
Chemiluminescent Immunoassay

Setup Schedule
Sun-Sat


Report Available
Within 24 hours


Limitations
SST needs to sit for 15-20 minutes for proper clot formation and to assure the absence of fibrin in the serum which can interfere with this assay.  Centrifuge and remove from cells ASAP.  Specimens must be free of all particulate matter which can interfere with the assay.  If testing cannot be performed within 48 hours from collection, ship frozen.  CK-MB is quite labile. CK-MB relative percent will be calculated only if Creatine Kinase, Total, Serum or Plasma (0020010) is ordered.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.