A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
HIGH MOLECULAR WEIGHT
Test Code500460
CPT Codes
85293
Preferred Specimen
"Plasma, frozen
"
"
Minimum Volume
"1 mL
"
"
Instructions
"Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a LabCorp PP transpak frozen purple tube with screw cap (LabCorp N° 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
"
Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
"
Transport Container
"Blue-top (sodium citrate) tube
"
"
Transport Temperature
"Freeze; up to four freeze/thaw cycles are acceptable. Stable at room temperature for up to four hours.
"
"
Specimen Stability
"Stable at room temperature for up to four hours.
"
"
Methodology
"Automated (LIATEST) enzyme immunoassay (EIA) "