A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Estradiol, Sensitive
Message"No isotopes administered 24 hours prior to venipuncture
"
"
Test Code
140244
CPT Codes
82670
Preferred Specimen
"Serum
"
"
Minimum Volume
"0.3 mL (Note: This volume does not allow for repeat testing.)
"
"
Instructions
"Refrigerate
If a red-top tube is used, transfer separated serum to a plastic transport tube.
"
If a red-top tube is used, transfer separated serum to a plastic transport tube.
"
Transport Container
"Red-top tube or gel-barrier tube
"
"
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
"Gross lipemia; recently administered isotopes
"
"
Methodology
"Radioimmunoassay (RIA) "
Limitations
"Estradiol levels tend to fluctuate dramatically during the perimenopausal transition.4 There is significant overlap of the expected range in menopausal women with values observed during normal menstrual cycles. Estradiol results obtained with different assay methods cannot be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor serial patient results.
"
"
Reference Range
"Age
(y)
Male
(pg/mL)
Female
(pg/mL)
0-6
0-15
0-15
7-10
0-15
0-70
11-12
0-40
10-300
13-15
0-45
10-300
>15
3-70
See below
Ovulating female:
Follicular phase
9-175
Luteal phase
44-196
Periovulatory
107-281
Oral contr
(y)
Male
(pg/mL)
Female
(pg/mL)
0-6
0-15
0-15
7-10
0-15
0-70
11-12
0-40
10-300
13-15
0-45
10-300
>15
3-70
See below
Ovulating female:
Follicular phase
9-175
Luteal phase
44-196
Periovulatory
107-281
Oral contr