Calcium, Ionized, Serum

Message
Centrifuge and send unopened gel-barrier tube with vacuum intact. It is critical that the vacuum not be disrupted. Exposure of the serum to room air causes a loss of carbon dioxide to the atmosphere. This changes the sample pH and can prevent the lab fro


Test Code
004804


Alias/See Also
Ca(++), Ionized, Serum; Calcium Filterable, Serum; Calcium Free, Serum; Calcium Unbound, Serum; Ionized Calcium, Serum


CPT Codes
82330

Preferred Specimen
Serum


Minimum Volume
1mL


Instructions
Centrifuge and send unopened gel-barrier tube with vacuum intact. It is critical that the vacuum not be disrupted. Exposure of the serum to room air causes a loss of carbon dioxide to the atmosphere. This changes the sample pH and can prevent the lab from measuring the ionized calcium. To ensure that testing can be performed, send a separate tube for ionized calcium and adhere a piece of labeling tape over the top of the tube with the following written on it "IONIZED CALCIUM-DO NOT OPEN."


Transport Container
Gel-barrier tube


Transport Temperature
Do NOT freeze.


Methodology
Ion-selective electrode (ISE)

Setup Schedule
Monday - Saturday 1st and 3rd shifts




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.