HCV Antibody Verification

Message
This assay is offered to provide verification of a positive HCV antibody screen obtained using the Siemens Advia Centaur HCV assay or other reagent with comparable sensitivity and specificity. Because the verification methodology is Roche ECLIA, this assay cannot be used to verify an initial screen performed with the Roche methodology.


Test Code
144090


Alias/See Also
Hep C; Non A


CPT Codes
86804

Preferred Specimen
Serum OR plasma


Minimum Volume
0.5mL


Instructions
If tube other than a gel-barrier tube is used, transfer separated serum or plasma to a plastic transport tube.


Transport Container
Red-top tube, gel-barrier tube, OR lavender-top (EDTA) tube


Transport Temperature
Refrigerate


Specimen Stability
Room temp: 4 days; Refrigerate/Frozen: 14 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Non-EDTA plasma specimen; PST gel-barrier tube


Methodology
Electrochemiluminescence (ECLIA)

Setup Schedule
Monday-Friday - 1st shift




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.