FIBRINOGEN
MessageCollect a full tube to the fill line, following standard venipuncture techniques. Do not over or under fill tubes as the ratio of blood to anticoagulant (9: 1) is necessary for accurate results. Gently Invert the tube three or four times immediately after venipuncture to ensure proper mixing of blood and anticoagulant.
Test Code
LAB314 FIB
Alias/See Also
FIB
CPT Codes
85384
Instructions
Processing Instructions (Lab use only): Within 1 hour of collection, centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again. Aliquot plasma into separate plastic vial leaving 0.25 mL in the bottom of centrifuged vial. Freeze plasma immediately (no longer than 4 hours after collection) at -20° C.Minimum Testing Volume: 1 mL (plasma) Transport Temperature: Frozen Stability: Ambient: 4 hours (Inpatient, plasma); 12 hours (Outpatient, plasma)Refrigerated : UnacceptableFrozen: (-20 °C): 1 month Causes for Rejection: Specimens submitted Refrigerated or greater than 4 hours after collection at room temperature, are short draws, clotted or have excessive hemolysis, icterus or lipemia.
Report Available
STAT 2-Hours|Routine 8-Hours|Timed 8-Hours|STAT 40-Minutes|Routine 2-Hours|Timed 1-Hours
Clinical Significance
1230140051