| A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
BILIRUBIN, TOTAL
MessageProtect specimen from bright light. Collect a full tube, following standard venipuncture techniques.
Test Code
LAB50 BILIT
Alias/See Also
BILIT
CPT Codes
82247
Instructions
Processing Instructions (Lab use only): Centrifuge and separate cells after clot formation and within 4 hours of collection.Protect specimen from bright light.Minimum Testing Volume: 0.1 mL Serum or Plasma Transport Temperature: Refrigerated , protect from bright light Stability: Ambient: 24 hoursRefrigerated : 7 daysFrozen: 6 months Causes for Rejection: Unlabeled, mislabeled, wrong tube type, QNS, hemolyzed, or lipemic.
Clinical Significance
1230130027
Last Updated: May 18, 2026