Gastrointestinal Profile, Stool,PCR

Message
ONLY TO BE COLLECTED MONDAY - THURSDAY. 
COLLECTING LATE THURSDAY, FRIDAY, WEEKENDS, and HOLIDAYS WILL RESULT IN A RECOLLECT
(Specimen to be sent to Quest as a STAT pick-up(M-TH); Quest will overnight to LabCorp)


Test Code
ORDER AS A MISC LabCorp TC#183480


Alias/See Also
GIPATHOGEN PANEL
GI PATHOGEN
GI PROFILE 


Includes
Adenovirus F 40/41;
Astrovirus; 


Campylobacter
Clostridium difficile toxin A/B; 


Cryptosporidium
Cyclospora cayetanensis


E coli O157; 


Entamoeba histolytica;
Enteroaggregative 
E coli (EAEC); 


Enteropathogenic E coli (EPAC);
Enterotoxigenic 
E coli (ETEC) lt/st; 


Giardia lamblia


Norovirus GI/GII; 


Plesiomonas shigelloides


Rotavirus A; 


Salmonella


Sapovirus; 


Shiga-like toxin-producing E coli (STEC) stx1/stx2; 


Shigella/enteroinvasive E coli (EIEC); 


Vibrio


Vibrio cholerae


Yersinia enterocolitica



Preferred Specimen
Stool placed in a stool culture transport vial (Para-Pak® C&S orange)


Minimum Volume
Add stool until level in Para-Pak® vial is at fill-line on vial label. Do not over fill.


Instructions
Introduce stool into orange Para-Pak® vial in small amounts such that level does not exceed fill-line on label. Cap securely and shake vial to distribute sample into the Cary-Blair preservative.


Transport Container
Para-Pak® C&S Orange (Cary-Blair)
 


Transport Temperature
Refrigerate or Room temperature storage 


Specimen Stability
Up to four days is acceptable.- 96 hours


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Specimen not received in Cary-Blair preservative medium; specimen vial leaking; specimen >96 hours since collection; frozen specimen; rectal swab; specimen below fill line on container (underfilled); container overfilled above line on label


Methodology
Polymerase chain reaction (PCR)

Report Available
2 - 3 days


Performing Laboratory
LabCorp


Last Updated: November 28, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.