Epstein-Barr Virus DNA, Quantitative Real-Time PCR

Test Code
EBVDNAPCR


Quest Code
10186


CPT Codes
87799

Preferred Specimen
1 mL whole blood collected in an EDTA (lavender-top), ACD (yellow-top) , or PPT (white-top) tube or
1 mL plasma collected in an EDTA (lavender-top), ACD (yellow-top), or PPT (white-top) tube or
1 mL CSF in a sterile, plastic, leak-proof container or
1 mL serum


Minimum Volume
0.5 mL


Other Acceptable Specimens
Bronchoalveolar lavage collected in a sterile, plastic, leak-proof container


Instructions
CSF: Collect in a sterile, plastic container and store refrigerated or frozen.


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Whole blood
Room temperature: 48 hours
Refrigerated: 8 days
Frozen: Unacceptable

All other specimens
Room temperature: 48 hours
Refrigerated: 8 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Heparin anticoagulant


Methodology
Real-Time Polymerase Chain Reaction

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Monday-Sunday Morning Report available: Next Day


Reference Range

Not Detected



Clinical Significance
Monitoring EBV DNA levels by quantitative PCR in patients at risk of EBV-associated lymphoproliferative disorders may allow timely recognition of virus reactivation and permit installment of antiviral treatment.


Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Dr
Chantilly, VA 20153


Last Updated: September 29, 2022


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.