Mercury, Serum/Plasma

Test Code
HGBLD


Quest Code
26499


CPT Codes
83825

Preferred Specimen
2 mL serum collected in a no additive trace metal-free (royal blue-top) tube or plasma collected in an EDTA trace metal-free (royal blue-top) tube


Minimum Volume
0.6 mL


Other Acceptable Specimens
Plasma collected in Greiner Trace Elements NH sodium heparin tubes


Instructions
Promptly centrifuge and separate serum or plasma into an acid-washed plastic screw-capped vial using approved guidelines.


Transport Container
Acid-washed, plastic screw-capped vial


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 14 days
Refrigerated: 30 days
Frozen: 15 months


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Polymer gel separation tube (PST) • Serum separator tube (SST)


Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

FDA Status
This test was developed and its performance characteristics have been determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.

Setup Schedule
Set up: Varies; Report Available: 3-7 days


Report Available
5 Days


Reference Range
Normally: Less than 6 mcg/L


Clinical Significance
Exposure Monitoring/Investigation


Performing Laboratory
NMS Labs
200 Welsh Rd
Horsham, PA 19044


Last Updated: March 10, 2022


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.