Deoxycorticosterone

Test Code
DEOXYCORT


Quest Code
90973


Alias/See Also
21-OH Progesterone
DOC
DEOXYCORT
11, Deoxycorticosterone


CPT Codes
82633

Preferred Specimen
3.0 mL serum collected in a red-top tube (no gel)


Minimum Volume
1.1 mL


Other Acceptable Specimens
Amniotic fluid - 3 mL (Can use EDTA or Na hep plasma)


Instructions
Spin down immediately and pour off into a plastic transport tube.


Transport Container
Plastic screw-cap vial


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: 7 days
Refrigerated: 7 days
Frozen: 28 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Serum separator tubes (SST) • Moderate hemolysis • Gross hemolysis • Grossly lipemic • Grossly icteric • Animal specimen


Methodology
Chromatography/Mass Spectrometry

Setup Schedule
Set up: Sun, Tues; Report available: 3-9 days


Reference Range
Adult Male≤16 ng/dL
   
Adult Female 
  Pre-Menopausal Mid Follicular≤18 ng/dL
  Pre-Menopausal Surge≤23 ng/dL
  Pre-Menopausal Mid Luteal≤19 ng/dL


Pediatric
AgeMale
(ng/dL)
Female
(ng/dL)
<30 daysNot establishedNot established
1-11 months≤69≤93
1 year≤66≤100
2 years≤64≤100
3 years≤63≤96
4 years≤63≤89
5 years≤62≤78
6 years≤58≤65
7 years≤51≤53
8 years≤44≤45
9 years≤38≤40
10 years≤31≤35
11 years≤26≤30
12 years≤22≤25
13 years≤20≤21
14 years≤20≤19
15 years≤20≤18
16 years≤20≤18
17 years≤19≤18


Clinical Significance
Deoxycorticosterone (DOC) is a weak mineralocorticoid derived from 21-hydroxylation of progesterone in the adrenal cortex. DOC is a precursor of corticosterone and aldosterone and, like cortisol, is under the primary control of ACTH.


Performing Laboratory
Quest Diagnostics Nichols Institute-San Juan Capistrano, CA
33608 Ortega Highway
San Juan Capistrano, CA 92675-2042



Last Updated: September 10, 2019


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.