VANCOMYCIN RANDOM

Message
Collection time MUST be documented on tube or requisition.


Test Code
VANC


Alias/See Also
VANCR


CPT Codes
80202

Preferred Specimen
1.0 mL Serum Red Top


Patient Preparation
Usual sampling time varies dependent upon desired measurement of peak or trough values.

Minimum Volume
0.1 mL


Other Acceptable Specimens
EDTA (Lavender)
Serum- SST or Tiger Top
Plasma Li Heparin


Specimen Stability
Room Temperature: 48 hours at 20-25°C
Refrigerated: 14 days 2-8°C
Frozen: 12 months at -20 °C. Freeze only once.
 


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Samples not labeled with First and Last Name and date of birth.
Grossly hemolyzed specimen.
 


Methodology
Immunoassay

Setup Schedule
24/7


Report Available
Same day


Reference Range
No reference range established for random samples.
Therapeutic trough 10- 20 ug/mL
Therapeutic peak 20-40 ug/mL


Clinical Significance
Vancomycin is a complex glycopeptide antibiotic, which has been used to treat penicillinase-producing staphylococci. It is the drug of choice for the treatment of methicillin and related beta lactam antibiotic resistant Staphylococcus aureus as well as for the treatment of serious gram-positive infections where allergies to penicillin or cephalosporin play a role. Vancomycin is also used in the treatment of antibiotic-induced enterocolitis associated with Clostridium difficile and streptococcal or enterococcal endocarditis, the latter in conjunction with an aminoglycoside, when penicillin or ampicillin is not an option. Monitoring of peak and trough serum or plasma levels is necessary due to potentially serious side effects including ototoxicity, nephrotoxicity, phlebitis, and reversible neutropenia.


Performing Laboratory
Frederick Memorial Hospital
400 W 7th St
Frederick, MD. 21701


Last Updated: November 1, 2024


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.