Paroxysmal Nocturnal Hemoglobinuria (PNH) with FLAER (High Sensitivity)

Test Code
CD5559


Quest Code
94148


Alias/See Also
CD55
CD59
CD5559
PNH with FLAER
FCM for PNH
FLAER, PNH


CPT Codes
88184, 88185 (x7), 88187<br><strong>This test code is for non-New York patient testing. For New York patient testing, use test code 38687.</strong>

Includes
Antibodies directed against CD45, glycophorin A, CD59, CD24, CD14, CD15, CD64, as well as FLAER.


Preferred Specimen
10 mL whole blood collected in a sodium heparin (green-top) tube, or acid citrate dextrose ACD-A (yellow-top) tube, or EDTA (lavender-top) tube


Minimum Volume
5 mL


Other Acceptable Specimens
Whole blood collected in: ACD-A (yellow-top) tube or EDTA (lavender-top) tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 72 hours
Refrigerated: Unacceptable
Frozen: Unacceptable


Methodology
Flow Cytometry (FC)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Daily; Report available: 2-3 days


Reference Range
See Laboratory Report


Clinical Significance
The high sensitivity and quantitative flow cytometry assay is used in the diagnosis and follow-up of patients with paroxysmal nocturnal hemoglobinuria (PNH). FLAER as well as antibodies directed against glycosylphosphosphatidylinositol (GPI)-linked antigens are used to evaluate for the presence of (GPI)-deficient cell populations down to a level of 0.01%.


Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Dr
Chantilly, VA 20153


Last Updated: September 12, 2019


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.