Hemoglobin A1c with eAG with Reflex to 1,5-Anhydroglucitol (1,5-AG)

Test Code
10379


Alias/See Also
Hemoglobin A1C with GlycoMark Reflex
503205 (LabCorp)


CPT Codes
83036

Includes
If Hemoglobin A1c is ≥6.5% and ≤8.0%, then 1,5-Anhydroglucitol (1,5-AG), Intermediate Glycemic Control will be performed at an additional charge (CPT code(s): 84378).


Preferred Specimen
1 full tube whole blood collected in EDTA (lavender-top) tube, and
1 mL serum, received spun


Minimum Volume
0.5 mL


Other Acceptable Specimens
1 full tube whole blood collected in EDTA (lavender-top) tube, and
1 mL plasma collected in EDTA (lavender-top) tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 7 days
Refrigerated: 7 days
Frozen: 28 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Sodium fluoride/oxalate (gray-top) tube • Heparinized plasma • Unspun serum separator tube


Methodology
Enzymatic

Setup Schedule
Set up: Daily; Report available: 1 day


Reference Range
<5.7 % of total Hgb


Clinical Significance
To assist with control of blood glucose levels, the American Diabetes Association (ADA) has recommended glycated hemoglobin testing (HbA1c) twice a year for patients with stable glycemia, and quarterly for patients with poor glucose control. Interpretative ranges are based on ADA guidelines.


Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Drive
Chantilly, VA 20153



Last Updated: November 21, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.