Urinalysis with Reflex Urine Culture

Test Code
1290


CPT Codes
81001-Urinalysis; 87086-Urine culture (if appropriate)

Includes
Includes color, appearance, specific gravity, pH, protein, glucose, ketones, blood, bilirubin, urobilinogen, nitrites, leukocyte esterase, and microscopic examination of urine sediment  .  

Urine culture will be performed if the urinalysis result finds any one of the following:
 ≥2+bacteria  OR
Any 2 of 3 of the following:
1. Positive nitrite
2. >=10 WBC/hpf
3. Positive leukocyte esterase
If criteria is met but epithelial cells are ≥ 2+, no culture will be performed, and a Repeat Urinalysis will be ordered for a specimen recollection.


Preferred Specimen

Container/Tube:Plastic urine container(s)
Specimen Volume: 12 mL from a random urine collection
Collection Instructions: No preservative.




Transport Temperature
Refrigerate <12 hours 


Specimen Stability
Room Temp:  <2 hours
Refrigerated:  <12 hours


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Specimens received room temp >2 hours from collection
Specimens received refrigerated >12 hours from collection


Methodology
International Remote Imaging Systems Automated Analyzer/Urisystem/Chemstrip

Setup Schedule
Monday through Sunday


Reference Range
Specific gravity: 1.002-1.030
pH: 5-8
Protein: none detected
Bilirubin: negative
Glucose: negative
Ketones: negative
Blood: negative
Urobilinogen: 0.1-1.0 mg/dL
Nitrite: negative
Leukocyte esterase: negative
Color: straw
Appearance: clear or cloudy

Microscopic:

RBC/hpf: 0-2/hpf
WBC/hpf: 0-5/hpf
Hyaline Casts/lpf: 0-2/lpf
Granular Casts/lpf: 0-2/lpf
Bacteria: None
Yeast: None
Epithelium: 1+
Crystals: None
Amorphous Material: None
Mucous: None to 1+

Urine Culture: No growth or no growth of significance


Performed By
CoxHealth



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.