HIV-1 RNA, Quantitative Real Time PCR with Reflex to Coreceptor Tropism, UDS

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
HV1QTR


CPT Codes
87536

Includes
If HIV-1 RNA, Quantitative, PCR is ≥1000 copies/mL, then HIV-1 Coreceptor Tropism, Ultradeep Sequencing will be performed at an additional charge (CPT code(s): 87906).


Preferred Specimen
3 mL plasma collected in an EDTA (lavender-top) tube


Minimum Volume
2.5 mL


Other Acceptable Specimens
Plasma collected in: PPT potasium EDTA (white-top) tube


Instructions
Samples submitted in primary tube will be rejected.

Freshly drawn specimens (whole blood) may be stored at 2-25°C for up to 24 hours prior to centrifugation. Separate plasma from cells within 24 hours of collection by centrifugation and immediately transfer to a transport tube. Follow manufacturer's instructions for collection tube handling.


Transport Container
Transport tube


Transport Temperature
Frozen


Specimen Stability
Room temperature: Unacceptable
Refrigerated: 5 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Samples received in primary collection tube • Gross hemolysis • Lipemia


Methodology
Real-Time Polymerase Chain Reaction

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics Infectious Disease. It has not been cleared or approved by the FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Mon-Sat; Report available: 2-4 days


Reference Range
HIV-1 RNA, QN,PCR Not detected copies/mL
HIV-1 RNA, QN, PCR Not detected Log copies/mL


Clinical Significance
This test is intended for use in conjunction with clinical presentation and other laboratory markers of disease progress for the clinical management of HIV-1 infected patients. The test can be used to assess patient prognosis by measuring the baseline HIV-1 RNA level or to monitor the effects of antiretroviral therapy by measuring changes in EDTA plasma HIV-1 RNA levels during the course of antiretroviral treatment. This test is not intended for use as a screening test for the presence of HIV-1 in blood or blood products or as a diagnostic test to confirm the presence of HIV-1 infection.


Performing Laboratory
Quest Diagnostics Nichols Institute-San Juan Capistrano, CA
33608 Ortega Highway
San Juan Capistrano, CA 92675-2042



Last Updated: November 30, 2021


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.