Creatinine, 24 HR Urine

Test Code
UCR24


CPT Codes
82570, 81050

Includes
  • Creatinine Urine Random, UCRE1
  • Volume measurement, UVOL
  • 24 hour calculation-UCREC
  • Time-Hours UHOUR


Preferred Specimen
URINE Timed (UTO)


Instructions
Patient instructions for 24 hour collection
Stress to the patient that for accurate test results on a 24 hour urine sample it is important for a complete and accurate collection be made.
Instruct patient to drink the same amount of liquid during the collection period that they normally consume, unless otherwise instructed by their physician. No alcoholic beverages should be consumed at this time.
Instructions to patient:
  1. Select a convenient time for starting the collection. You must finish the collection at the same time 24 hours later.
  2. Empty your bladder and discard this urine. Note the date and time you did this.
  3. From this time on, collect ALL urine you pass during the day and night for the duration of the 24 hour period. Pour this urine into the container provided by the Laboratory.
  4. Keep the urine refrigerated or on ice throughout the collection process.
  5. At exactly 24hours from the start of collection (see time documented in #2), empty you bladder. Note the date and time:
  6. After collection is complete, bring the urine and instruction sheet to the Laboratory as soon as possible.


Transport Container
Urine specimens should be collected into a clean, leak-proof container. If urine must be collected with a preservative for other analytes, 6N HCL or Boric Acid can be used.


Specimen Stability
Creatinine in urine is stable for 2 days at room temperature (15-25°C) and for 6 days refrigerated (2 - 8°C).



Setup Schedule
24x7


Report Available
24x7


Reference Range
Female:   0.6-1.8 g/24 hr
Male:       0.8-2.0  g/24 hr


Performing Laboratory
CRMC Laboratory
CCMC Laboratory



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.