Resources

ESTRADIOL, SENSITIVE

Test Code
ESTLS


CPT Codes
82670

Preferred Specimen
1 Gold tube (gel separator)


Minimum Volume
0.2 mL


Other Acceptable Specimens
1 Lavender tube (EDTA) or
1 Green tube (Lithium heparin)


Instructions
Centrifuge for complete separation of serum or plasma and red cells. Aliquot plasma into a transfer tube.


Transport Temperature
Refrigerate


Specimen Stability
  • 15-30°C up to 8 hours
  • 2-8°C up to 7 days
  • Frozen samples are stable


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolyzed samples will be rejected


Methodology
Chemiluminescent immunoassay

Setup Schedule
M, T, W, Th, F, Sa, Su


Report Available
Within 24 hours of receipt at the performing laboratory.


Reference Range
Non-Pregnant Females pg/mL
Early-follicular 22.4 - 115
Mid-follicular 25.0 - 115
Ovulatory Peak 32.1 - 517
Mid-Luteal 36.5 - 246
Post-Menopausal Females pg/mL
Not on hormone therapy 0 - 25.1
Adult Males pg/mL
  0 - 31.5
Pediatric
Sex Age pg/mL
Male or Female 0 - <1 year 0 - 38.2
Female, pre-puberty 1 - <12 years 0 - 16.0
Female, puberty 12 - <19 years 0 - 196
Male, pre-puberty 1 - <12 years <15
Male, puberty 12 - <19 years 0 - 34.8


Clinical Significance
Monitors the level of the biologically most active estrogen.


Performed By
Alverno Laboratories

Performing Laboratory
Alverno Central Lab  
NCHB2 (Chemistry, Beckman DxI)


Last Updated: June 9, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.