This test was developed and its performance characteristics determined by CompuNet Clinical Laboratories. It has not been cleared or approved by the U.S. Food and Drug Administration (FDA). The FDA has determined that such clearance or approval is not necessary. This test is used for clinical purposes. It should not be considered as investigational or for research. This laboratory is certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) as qualified to perform high-complexity testing.
This test was developed and its performance characteristics determined by CompuNet Clinical Laboratories. It has not been cleared or approved by the U.S. Food and Drug Administration (FDA). The FDA has determined that such clearance or approval is not necessary. This test is used for clinical purposes. It should not be considered as investigational or for research. This laboratory is certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) as qualified to perform high-complexity testing.
Test Code
CMVDNA
Alias/See Also
74789;
Cytomegalovirus DNA,
QN Real Time PCR
Cytomegalovirus DNA,
QN Real Time PCR
CPT Codes
87497
Preferred Specimen
2 mL plasma K3EDTA (lavender top tube).
This test is for both inpatient and outpatient blood and plasma specimens.
This test is for both inpatient and outpatient blood and plasma specimens.
Minimum Volume
0.5 mL plasma
0.5 mL whole blood
5 mL Urine
0.5 mL whole blood
5 mL Urine
Instructions
Centrifuge the tube for at least 10 minutes. Transfer plasma to a completely labeled plastic transport tube within 6 hours of collection. Freeze plasma pour off.
NOTE: For pediatric collection please submit whole blood testing. (It is not necessary to collect plasma fromt he pediatric tube)
NOTE: For pediatric collection please submit whole blood testing. (It is not necessary to collect plasma fromt he pediatric tube)
Transport Container
K3EDTA (Lavender-top) tube, Sterile plastic pour off tube
Transport Temperature
Plasma = Frozen or refrigerated
Whole Blood = Refrigerated
Whole Blood = Refrigerated
Specimen Stability
Plasma
Room Temperature = unacceptable
Refrigerated = 8 hours (24 hrs after first thaw)
Frozen = 5 days
Whole Blood
Room Temperature = 12 hours
Refrigerated = 5 days
Frozen = unacceptable
Room Temperature = unacceptable
Refrigerated = 8 hours (24 hrs after first thaw)
Frozen = 5 days
Whole Blood
Room Temperature = 12 hours
Refrigerated = 5 days
Frozen = unacceptable
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Rejected for hemolysis, Plasma if received at room temperature and whole blood if received frozen.
Methodology
Real Time Polymerase Chain Reaction (PCR) for the amplification of a well conserved region of CMV UL83 Gene.
Setup Schedule
Monday - Sunday
Report Available
36 Hours
Performing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine, OH 45439